Replaced Loc-line with spray bars in custom 45g

45g ‘Lamprologus’ caudopunctatus tank. Yes, the tank is level, but my camera wasn’t. Photo by the author.

Though the two custom 45g shellie tanks have been set up for a while, my original plumbing on each tank created a problem with the filter outflow. The Loc-line Y-reducers I was using on each tank were concentrating the water flow too much. 

Loc-line Y-reducer. Photo by the author.

Specific info on the tanks can be found in this post from back in March. Because the outflow bulkheads are only about 3″ below the top of each tank and near each end, I was limited in how much I could adjust the Y-reducers – up, down, rotated, etc. Facing the reducers up toward the water surface was creating too much surface agitation from the two outlets of the Y. Facing the reducers downward too much was blowing sand off the bottom of the tank. Remember, these tanks are only 12″ deep, thus the distance from the reducer outflow to the bottom of the tank was only 8″. Taking into consideration at least 1-2″ of sand bed in each tank, there isn’t much distance between the outflow and the sand. I just couldn’t find a sweet-spot with the Ys. In fact, in hindsight, they weren’t a good option with these set-ups. 

I had other options with the Loc-line (e.g., replace the reducers with other nozzle types like flares or round). I also could either reduce the filter flow or use different filters. However, I like using canisters on these sized tanks. The solution to more evenly distribute the outflow horizontally across the surface was use spray bars. 

PVC spray bar. Photo by the author.

For that, I took some 1″ PVC pipe and cut two 9″ lengths. I then drilled several 1/4″ holes approximately 3/4″ apart into the length of each pipe. After removing the Loc-line Y-reducers (which were screwed directly into the bulkheads), I screwed in a threaded male-to-slip PVC connector into each bulkhead. I then capped off each of the two 9″ pipe ends and inserted the pipes in the PVC connectors. Voila! Problem solved. There wasn’t any need to 1) glue the pipes into the slip connectors or 2) glue the end caps on the pipes because the outflow from the canisters isn’t strong enough to displace either. 

The outflow from the filters now flows along the surface length of each tank. I have also recovered a large percentage of the tank floor, increasing the amount of space for the shellies. With the Loc-line reducers, the flow was strong across the bottom when angled even slightly downward, pretty much eliminating that section of the tank for occupancy. Most shellies don’t like high water flow and won’t occupy shells near such flow. 

 

 

Leave a Comment